Vinci-Biochem Srl
Via Ponte di Bagnolo, 10
50059 Vinci (Firenze) Italy

Tel: +39  0571 568 147 e 0571 568 135

Jaica

 

The Source for Unique Oxidative Stress Markers 

The Japan Institute for the Control of Aging (JaICA) è specializzata e conosciuta nel mondo per gli anticorpi e gli Assay Kits per ricerca sullo Stress Ossidativo e per la rilevazione di Oligoelementi (Ca, Cu, Fe, Mg, Zn, UIBC). Jaica è distributa in Italia da Vinci-Biochem Srl.

 

Jaica

 

 

  

Jaica_Oxidative_Stress
Unique Oxidative Stress Markers 
 
 
 

  



ProductCodeSizePrice € Preventivo / Ordina
ANTI-4-HYDROXY-2-HEXENAL [4-HHE], MAB (HHE53)
Source / Host:
Ascites
Reactivity:
All, Human
Clone:
HHE53
Application:
IHC
JAI-MHH-030N 30 µg inquire  
ANTI-4-HYDROXY-2-NONENAL [4-HNE], MAB (HNEJ-2)
Source / Host:
Ascites
Reactivity:
All, Human
Clone:
HNEJ-2
Application:
IHC, WB
JAI-MHN-020P 20 µg inquire  
ANTI-4-HYDROXY-2-NONENAL [4-HNE], MAB (HNEJ-2)
Source / Host:
Ascites
Reactivity:
All, Human
Clone:
HNEJ-2
Application:
IHC, WB
JAI-MHN-100P 100 µg inquire  
ANTI-7-KETOCHOLESTEROL [7-KC], MAB (35A)
Reactivity:
All, Human
Clone:
35A
Application:
IHC
JAI-MKC-020N 20 µg inquire  
ANTI-8-HYDROXY-2'-DEOXYGUANOSINE [8-OHDG], MAB (N45.1)
Source / Host:
Ascites
Reactivity:
All
Clone:
N45.1
Application:
ELISA, IHC
JAI-MOG-020P 20 µg inquire  
ANTI-8-HYDROXY-2'-DEOXYGUANOSINE [8-OHDG], MAB (N45.1)
Source / Host:
Ascites
Reactivity:
All
Clone:
N45.1
Application:
ELISA, IHC
JAI-MOG-100P 100 µg inquire  
8-OHDG CHECK ELISA KIT
Sample Type:
Urine
Assay Range:
0.5 to 200 ng/mL
Manual PDF:
JAI-KOG-200SE 1 Kit inquire  
8-OHDG CHECK ELISA KIT (HIGH SENSITIVITY)
Sample Type:
Plasma, Serum, Urine
Assay Range:
0.125 to 10 ng/mL
Manual PDF:
JAI-KOG-HS10E 1 Kit inquire  
ANTI-ACROLEIN [ACR], MAB (5F6)
Reactivity:
All, Human
Clone:
5F6
Application:
IHC
JAI-MAR-020N 20 µg inquire  
ANTI-ACROLEIN [ACR], MAB (5F6)
Reactivity:
All, Human
Clone:
5F6
Application:
IHC
JAI-MAR-100N 100 µg inquire  
CALCIUM COLORIMETRIC ASSAY KIT (CHLOROPHOSPHONAZO-III METHOD)
Sample Type:
Cell Lysate, Plasma, Saliva, Serum, Tissue Supernatant, Urine
Assay Range:
0.2 - 20mg/dL
Manual PDF:
JAI-CCA-020 200 tests inquire  
CALCIUM COLORIMETRIC ASSAY KIT (O-CRESOLPHTHALEIN METHOD)
Sample Type:
Cell Lysate, Plasma, Saliva, Serum, Tissue Supernatant, Urine
Assay Range:
0.2 - 30mg/dL
Manual PDF:
JAI-CCA-030 200 tests inquire  
COPPER COLORIMETRIC ASSAY KIT (3,5-DIBR-PAESA METHOD)
Sample Type:
Cell Lysate, Plasma, Saliva, Serum, Tissue Supernatant, Urine
Assay Range:
3 - 400µg/dL
Manual PDF:
JAI-CCU-400 100 tests inquire  
ANTI-CROTONALDEHYDE [CRA], MAB (82D3)
Reactivity:
All, Human
Clone:
82D3
Application:
IHC
JAI-MCA-030N 30 µg inquire  
ANTI-DIBROMO-TYROSINE [DIBRY], MAB (3A5)
Reactivity:
All, Human
Clone:
3A5
Application:
ELISA, IHC, WB
JAI-MBY-020P 20 µg inquire  
ANTI-DITYROSINE [DT], MAB (1C3)
Reactivity:
All, Human
Clone:
1C3
Application:
ELISA, IHC, WB
JAI-MDT-020P 20 µg inquire  
HEXANOYL-LYS [HEL] ELISA KIT
Sample Type:
Serum, Urine
Assay Range:
2 - 700 nmol/L
Manual PDF:
JAI-KHL-700E 1 Kit inquire  
ANTI-HEXANOYL-LYS [HEL], MAB (5F12)
Reactivity:
All, Human
Clone:
5F12
Application:
ELISA, IHC, WB
JAI-MHL-021P 20 µg inquire  
IRON COLORIMETRIC ASSAY KIT (FERROZINE METHOD)
Sample Type:
Cell Lysate, Plasma, Saliva, Serum, Tissue Supernatant, Urine
Assay Range:
5 - 1'000µg/dL
Manual PDF:
JAI-CFE-005 100 tests inquire  
IRON COLORIMETRIC ASSAY KIT (NITROSO-PSAP METHOD)
Sample Type:
Cell Lysate, Plasma, Saliva, Serum, Tissue Supernatant, Urine
Assay Range:
10 - 1'000µg/dL
Manual PDF:
JAI-CFE-010 100 tests inquire  
MAGNESIUM COLORIMETRIC ASSAY KIT (XYLIDYL BLUE-I METHOD)
Sample Type:
Cell Lysate, Plasma, Saliva, Serum, Tissue Supernatant, Urine
Assay Range:
0.2 - 3.5mg/dL
Manual PDF:
JAI-CMG-035 100 tests inquire  
ANTI-MALONDIALDEHYDE [MDA], MAB (1F83)
Reactivity:
All, Human
Clone:
1F83
Application:
IHC
JAI-MMD-030N 30 µg inquire  
ANTI-METHYLGLYOXAL [MG], MAB (3C)
Reactivity:
All, Human
Clone:
3C
Application:
IHC, WB
JAI-MMG-030N 30 µg inquire  
ANTI-NITROTRYPTOPHAN (NW), MAB (117C)
Reactivity:
All, Human
Clone:
117C
Application:
IHC, WB
JAI-MNW-020P 20 µg inquire  
NUCLEASE P1 (FROM PENICILLIUM CITRINUM)
JAI-OPNUCP1 500 Units inquire  
ANTI-THYMIDINE GLYCOL [TG], MAB (2E8)
Reactivity:
All, Human
Clone:
2E8
Application:
IHC
JAI-MTG-100P 100 µg inquire  
TOTAL ANTIOXIDANT CAPACITY (PAO) TEST KIT
Sample Type:
Plasma, Serum
Assay Range:
21.9 - 4378 µmol/L (cupric ion reducing power)
Manual PDF:
JAI-KPA-050 1 Kit inquire  
UIBC COLORIMETRIC ASSAY KIT (BATHOPHENANTHROLINE METHOD)
Sample Type:
Plasma, Serum
Assay Range:
10 - 800µg/dL
Manual PDF:
JAI-CBC-800 100 tests inquire  
ULTRA FILTER UNIT (MW CUT OFF 10KDA)
JAI-OPF-010E 1 Unit inquire  
ZINC COLORIMETRIC ASSAY KIT (5-BR-PAPS METHOD)
Sample Type:
Cell Lysate, Plasma, Saliva, Serum, Tissue Supernatant, Urine
Assay Range:
4 - 1000µg/dL
Manual PDF:
JAI-CZN-001 100 tests inquire  



  • Come Contattarci - Contact Us:

    Semplicemente preferiamo che ci chiami o ci mandi una mail.
    E' anche possibile compilare il modulo contatti

    Vinci-Biochem Srl
    Via Ponte di Bagnolo, 10
    50059 Vinci (Firenze) Italy
    vb@vincibiochem.it
    Tel:+39 0571 568147
    P. IVA 05706610481
L o a d i n g