Vinci-Biochem Srl
Via Ponte di Bagnolo, 10
50059 Vinci (Firenze) Italy

Tel: +39  0571 568 147 e 0571 568 135

M-Phisyl-chloride

  CDX-M0004-M100 100 mg

 
Synonyms: 2-Methoxy-5-(N-phthalimidinyl)benzenesulfonyl chloride
 
Chemodex
M-Phisyl-chloride

Data Sheet:     SDS:    

Source / Host
Synthetic.  

CAS
126565-42-2  

Purity
>97% (Elemental Analysis)  

Shipment
Ambient  

Short Term Storage
+4°C  

Long Term Storage
-20°C  

Shelf Life
Stable for at least 2 years after receipt when stored at -20°C.  


Description
 
Chemical. CAS: 126565-42-2. Formula: C15H12ClNO4S. MW: 337.78. Synthetic. It is known that phenol and p-cresol are promoters of skin tumors and also urinary excretion of phenol and p-cresol is increased by exposure to benzene, which has hemopoietic toxicity, and toluene, respectively. Therefore, the determination of phenol and p-cresol is important in clinical chemistry and toxicology. Because phenol and p-cresol are present in urine as sulfate or glucuronide conjugates, they are hydrolyzed enzymatically or with acid, followed by distillation or extraction with organic solvent prior to measurement by GC or HPLC. However, these GC and HPLC methods require relatively large sample volumes (more than 1 ml) because of their insufficient sensitivities for measuring small amounts of phenol and p-cresol. In the general, the application of fluorescent labeling techniques to HPLC result in a sensitive and selective method. Some acyl chlorides are known to react with phenolic hydroxy group to form esters. It is known that 4-(N-phthalimidinyl)benzensulfonyl chloride Phisyl-Cl7, having sulfonyl chloride, reacted with phenol to give the corresponding highly fluorescent sulfonyl ester. The sensitivity of Physil-Cl was compared with Dansyl-Cl and DPS-Cl, which are analogous to Physil-Cl as fluorescent labeling reagents having sulfonyl chloride group. The labeling reaction of phenol with Dansyl-Cl and DPS-Cl were carried out according to the method of Ruiter et al.5 and the peaks were detected at the each fluorescence maxima wavelength (Ex350nm a Em550nm for Dansyl-Cl, and Ex320nm a Em386nm for DPS-Cl). Peak height of Phisyl derivative was higher about 85-and 7,3-fold than thosse of Dansyl derivative and DPS derivative, respectively. Among these three reagents, Phisyl-Cl was the most sensitive.
 


 
 
 
 

ESCLUSIVAMENTE PER USO DI RICERCA (RUO) e non per uso terapeutico o diagnostico su uomini o animali. Il prodotto NON è un Dispositivo Medico o un Diagnostico in Vitro.
PRODUCT FOR RESEARCH USE ONLY (RUO) and not for therapeutic or diagnostic use on humans or animals. The product is NOT a Medical Device or an In-Vitro Diagnostic (IVD).
 
  • Come Contattarci - Contact Us:

    Semplicemente preferiamo che ci chiami o ci mandi una mail.
    E' anche possibile compilare il modulo contatti

    Vinci-Biochem Srl
    Via Ponte di Bagnolo, 10
    50059 Vinci (Firenze) Italy
    vb@vincibiochem.it
    Tel:+39 0571 568147
    P. IVA 05706610481
L o a d i n g