Vinci-Biochem Srl
Via Ponte di Bagnolo, 10
50059 Vinci (Firenze) Italy

Tel: +39  0571 568 147 e 0571 568 135

Anti-Nav1.2 Na+ Channel Antibody (BSA and Azide free)

  ABI-75-024-CF 100 µL

 
Synonyms: Sodium channel protein type 2 subunit alpha (Sodium channel protein brain II subunit alpha) (Sodium channel protein type II subunit alpha) (Voltage-gated sodium channel subunit alpha Nav1.2)
 
Antibodies Inc / Neuromab / VQ
Anti-Nav1.2 Na+ Channel Antibody (BSA and Azide free)

Data Sheet:    

Reactivity
Feline, Human, Mouse, Non-Human Primate, and Rat  

Applications
WB, IHC, ICC, ELISA  

Clone
K69/3  

Concentration
1 mg/mL  

Shipment
Shipped on ice packs  

Long Term Storage
Aliquot and store at ≤ -20°C for long term storage. For short term storage, store at 2-8°C. For maximum recovery of product, centrifuge the vial prior to removing the cap.  

Shelf Life
12 months from date of receipt  


Description
 
Our carrier-free Anti-Nav1.2 Na+ channel mouse monoclonal primary antibody from NeuroMab is produced in-house from hybridoma clone K69/3. It detects feline, human, mouse, non-human primate, and rat Nav1.2 Na+ channel, and is purified by Protein A chromatography. It is great for use in IHC, ICC, IP, WB. - Nav1.2 Na+ channel (sodium channel, voltage-gated, type II, alpha subunit/ SCN2A) is a member of voltage-gated sodium ion channel subunit family. It is encoded by gene Scn2a in human.The channel switches between open and close conformation in response to the voltage difference accross the membrane. Nav1.1 Na+ channel is a sodium selective channel that maintains Na+ homeostasis by allowing Na+ ions to pass in accordance of their electrochemical gradient.Nav1.2 Na+ channel is implicated in the regulation of hippocampal replay, whose waves ripples (SPW-R) condition memories. It is heterogeneously expressed in the brain, and mutations in this gene have been linked to several cases of seizures, autism and bipolar disorders. -
 


 
 
 
 

ESCLUSIVAMENTE PER USO DI RICERCA (RUO) e non per uso terapeutico o diagnostico su uomini o animali. Il prodotto NON è un Dispositivo Medico o un Diagnostico in Vitro.
PRODUCT FOR RESEARCH USE ONLY (RUO) and not for therapeutic or diagnostic use on humans or animals. The product is NOT a Medical Device or an In-Vitro Diagnostic (IVD).
 
  • Come Contattarci - Contact Us:

    Semplicemente preferiamo che ci chiami o ci mandi una mail.
    E' anche possibile compilare il modulo contatti

    Vinci-Biochem Srl
    Via Ponte di Bagnolo, 10
    50059 Vinci (Firenze) Italy
    vb@vincibiochem.it
    Tel:+39 0571 568147
    P. IVA 05706610481
L o a d i n g