Vinci-Biochem Srl
Via Ponte di Bagnolo, 10
50059 Vinci (Firenze) Italy

Tel: +39  0571 568 147 e 0571 568 135

Anti-Aquaporin 2 (Ser261) Antibody

  ABI-p112-261t 25 µL

 
Synonyms: ADH water channel antibody, AQP 2 antibody, AQP CD antibody, AQP-2 antibody, AQP-CD antibody, AQP2 antibody, AQP2_HUMAN antibody, AQPCD antibody, Aquaporin 2 collecting duct antibody, Aquaporin CD antibody, Aquaporin-2 antibody, Aquaporin-CD antibody, Aqu
 
PHOSPHOSOLUTION & STEPHEN ALL
Anti-Aquaporin 2 (Ser261) Antibody

Data Sheet:    

Reactivity
Human, Mouse, and Rat  

Applications
ELISA, WB, IHC, ICC, IP  

Concentration
Lot Dependent  

Shipment
Blue Ice  

Long Term Storage
Storage at -20°C is recommended, as aliquots may be taken without freeze/thawing due to presence of 50% glycerol. Stable for at least 1 year at -20°C.  

Shelf Life
After date of receipt, stable for at least 1 year at -20°C.  


Description
 
Our Anti-Aquaporin 2 (Ser261) rabbit polyclonal phosphospecific primary antibody from PhosphoSolutions is produced in-house. It detects human, mouse, and rat Aquaporin 2 (Ser261) and is antigen affinity purified from pooled serum. It is great for use in WB, IHC, ICC, IP. - Aquaporin 2 (AQP2) is a hormonally regulated water channel located in the renal collecting duct. Mutations in the AQP2 gene cause hereditary nephrogenic diabetes insipidus in humans (Iolascon et al.,2007). A vasopressin induced cAMP increase results in the phosphorylation of AQP2 at serine-256 and its translocation from the intracellular vesicles to the apical membrane of principal cells (van Balkom et al., 2002). Recently, serine-261 has been identified as a novel phosphorylation site on AQP2 and levels of phosphorylated S261 have been shown to decrease with vasopressin treatment suggesting its involvement in vasopressin-dependent AQP2 trafficking (Hoffert et al., 2007) -
 


 
 
 
 

ESCLUSIVAMENTE PER USO DI RICERCA (RUO) e non per uso terapeutico o diagnostico su uomini o animali. Il prodotto NON è un Dispositivo Medico o un Diagnostico in Vitro.
PRODUCT FOR RESEARCH USE ONLY (RUO) and not for therapeutic or diagnostic use on humans or animals. The product is NOT a Medical Device or an In-Vitro Diagnostic (IVD).
 
  • Come Contattarci - Contact Us:

    Semplicemente preferiamo che ci chiami o ci mandi una mail.
    E' anche possibile compilare il modulo contatti

    Vinci-Biochem Srl
    Via Ponte di Bagnolo, 10
    50059 Vinci (Firenze) Italy
    vb@vincibiochem.it
    Tel:+39 0571 568147
    P. IVA 05706610481
L o a d i n g